auto infrared detector switch for cooridor , high quality , best price
infrared detector switch
Intelligent infrared sensor switch is pyroelectric infrared sensors, daylight detection sensor, High sensitivity and reliability.
This switch is especially suitable for classrooms, schools, libraries, offices, hospitals, computer room,
meeting rooms and other public places.
Features:
1.auto-sensing, entering the region, the lights, leaves auto delay off.
2.during each effective, human activities will cause a delay sensing switch automatically extended time period.
3.Adjustable light intensity: adjustable CDS.
4.Delaytime adjustable.
Technical parameters:
1.Operating voltage: 110VAC or 220VAC.
2.sensing distance: the largest mounted side wall 7 meters (adjustable).
3.Load type: fluorescent, LED energy saving lamps, all kinds of lamps.
4.Power consumption: < 0.25W
5.Load power: < 600W
6.Detection angle:110 --- 140 degrees
7.Open the light intensity setting range :1-250LUX (adjustable)
8.Output Delay: 30 seconds --- 30 minute (adjustable)
9.Ambient temperature: -10 ~ +50 °C
10.Product Size: φ95 × 35mm
11.Contact the working life: 50 million
Instructions for use:
1. according diagram connected switch, power warm-up time about 2 minutes. After warm-up, the switch enter
normal operation. When daylights, the switch automatically closed.
Use Note:
1.Wiring installation shall not be charged, non-load short-circuit, to be installed after the power.
2.Strict accordance with the wiring diagram wiring, if a wrong can damage the switch, resulting in power line fault.
3.Prohibited use of super-power range, otherwise it will burn switch.
4.Installation environment: switch installation location as possible from the load is greater than 1 meter, not the
switch installed in direct sunlight or air flow areas. Switch can not be placed where there are high-power radio
frequency radiation (example: radio, radio, the antenna).